Manufacturing Services  |  Architectural Systems  |  R54 








R54SG glass facades without mouldings


R54 Facade System

R54 is a completely new system and thus is not directly based on any Nordic Aluminium R system. The design work is aimed at achieving a result whose tightness, ease of installation and thermal insulation capabilities would can meet today's high and challenging standards.

The system frame is primarily built using a lap joint technique, where the transverse frame profile is lapped over the upright frame profile. The R54 system profiles have channels for draining off possible condensate water from the rebates. A security chamber has been moulded in the upright profile, which forms levels on the frame profiles through which no screws or brackets pass. The resulting bi-level structure has clearly separated dry and wet sides. An end-to-end joint technique can also be used in the R54 system; in this case, transverse frame profiles are used.

The inner and outer gaskets in the R54 system have two hardnesses: the gasket corners are made of softer, cellular EPDM rubber, and the actual gasket is made of EPDM rubber, which ensures tightness. There are two types of outer gaskets, horizontal and vertical. The width of the outer gaskets is 50 mm. Where they cross, the outer gaskets lap over each other, and thus form a solid and continuous sealing at the crossing points. The gaskets do not obstruct the light hole at all.

The material thicknesses and other properties of the thermal breaks have been designed to achieve the best thermal insulation performance possible.

The architraves are the same as those used in the R53 system, which means that all architraves in the R53 system are included in the R54 system selection as such. Separate support profiles are used for glass support, which transmit the dead load of the glass to the transverse frame.

The thermic properties of the new R54 system are well- suited to the cold Northern conditions. In computer modelling, the average U value of a 3K4-15 window (size 1200 mm x 1200 mm) using R54 frames was 1.19 W/m2K.

The R54 system also includes glass facades without mouldings R54SG, where the glass panes are attached mechanically at the ends of the insulation glass elements. The system allows building the glazing as a four-sided construction which has no mouldings at all, or a two-sided construction which has either vertical or horizontal mouldings.

The R54 system can also be used in light ceilings if there is no need for outer condensate channels. The system includes solutions for glass walls with alternating angles, like curved facades designed using a fraction line. The R54 profiles with alternating angles enable free angle changes of 0°-10° in a wall.

The contents of technical folder is in two different formats, pdf-files for browsing and Autocad-files for editing/browsing.


R54 (PDF, 20343 kb)

R54_sis.dwg (DWG, 127 kb)

R54_Varit.dwg (DWG, 106 kb)

R54_1_1.dwg (DWG, 99 kb)

R54_1_2.dwg (DWG, 73 kb)

R54_1_3.dwg (DWG, 225 kb)

R54_1_4.dwg (DWG, 173 kb)

R54_1_5.dwg (DWG, 152 kb)

R54_1_6.dwg (DWG, 175 kb)

R54_1_7.dwg (DWG, 973 kb)

R54_1_8.dwg (DWG, 524 kb)

R54_1_9.dwg (DWG, 63 kb)

R54_2_1.dwg (DWG, 717 kb)

R54_2_2.dwg (DWG, 281 kb)

R54_2_3.dwg (DWG, 246 kb)

R54_2_4.dwg (DWG, 135 kb)

R54_3_1.dwg (DWG, 766 kb)

R54_3_2.dwg (DWG, 351 kb)

R54_4_1.dwg (DWG, 224 kb)

R54_4_2.dwg (DWG, 523 kb)

R54_4_3.dwg (DWG, 281 kb)

R54_5_1.dwg (DWG, 166 kb)

R54_5_2.dwg (DWG, 144 kb)

R54_5_3.dwg (DWG, 193 kb)

R54_5_4.dwg (DWG, 185 kb)

R54_6_1.dwg (DWG, 343 kb)

R54_8_1.dwg (DWG, 232 kb)

R54_8_2.dwg (DWG, 171 kb)

R54_8_3.dwg (DWG, 176 kb)

R54_9_1.dwg (DWG, 159 kb)

R54_9_2.dwg (DWG, 114 kb)

R54_9_3.dwg (DWG, 777 kb)

R54_9_4.dwg (DWG, 121 kb)

R54_9_5.dwg (DWG, 155 kb)

R54_9_6.dwg (DWG, 94 kb)

R54_9_7.dwg (DWG, 111 kb)

R54_10_1.dwg (DWG, 277 kb)

R54_10_2.dwg (DWG, 470 kb)

R54_10_3.dwg (DWG, 223 kb)

R54_11_1.dwg (DWG, 445 kb)

R54_11_2.dwg (DWG, 205 kb)

R54_12_1.dwg (DWG, 286 kb)

R54_12_2.dwg (DWG, 6403 kb)

R54_13_1.dwg (DWG, 334 kb)

R54_13_2.dwg (DWG, 308 kb)

R54_13_3.dwg (DWG, 318 kb)

R54_13_4.dwg (DWG, 311 kb)

R54_13_5.dwg (DWG, 356 kb)

R54_13_6.dwg (DWG, 353 kb)

R54_13_7.dwg (DWG, 227 kb)

R54_13_8.dwg (DWG, 40 kb)

R54_14_1.dwg (DWG, 258 kb)

R54_14_2.dwg (DWG, 248 kb)

R54_14_3.dwg (DWG, 261 kb)

R54_14_4.dwg (DWG, 258 kb)

R54_14_5.dwg (DWG, 210 kb)

R54_15_1.dwg (DWG, 67 kb)

R54_15_2.dwg (DWG, 55 kb)


© 2004 Nordic Aluminium Oyj | Updated 13.08.2004 | Legal Notice